The PagerDuty integration sends your monitor alerts to a PagerDuty service. When a monitor goes down, an incident opens in PagerDuty. When the monitor is back up, the incident is resolved automatically. Other alerts, such as SSL and domain expiry or slow response time, can be sent to PagerDuty too.
Before you start
The PagerDuty integration is available on the Team, Scale, and Enterprise plans.
You need access to the PagerDuty service that should receive the alerts.
Step 1: Get the integration key in PagerDuty
UptimeRobot uses the PagerDuty Events API v2. You need the Integration Key of a specific PagerDuty service, not a general PagerDuty REST API key.
In PagerDuty, go to Services and open the service that should receive UptimeRobot alerts.
Open the Integrations tab.
Add an Events API v2 integration, or open an existing one.
Copy the Integration Key (also called the routing key).
Step 2: Add the integration in UptimeRobot
In your UptimeRobot dashboard, go to Integrations and open the Connectors & Incident management tab.
Find PagerDuty and click Add.
In the PagerDuty integration key, paste the 32-character Integration Key from step 1.
Choose the PagerDuty Service region: US or EU. It must match the region of your PagerDuty account.
Leave Auto-resolve incidents after up event on if you want PagerDuty incidents to close when the monitor is back up. If you turn it off, every event is sent to PagerDuty as a trigger, including Up events. In that case, Up events open (or re-trigger) a PagerDuty incident instead of resolving it.
In Events to notify about, choose what to send: Down events, Up events, and SSL & Domain expiry. Other alerts on your monitors, such as slow response time, visual change, third-party service (dependency), and alert storm notifications, are also sent to PagerDuty.
Click Create integration.
Step 3: Turn it on for your monitors
On the Monitors page, click the ⋯ menu next to a monitor and choose Integrations & team. You can also open the monitor, click Edit, and switch to the Integrations & Team tab.
Under Connect integrations, turn on the PagerDuty integration.
Click Save changes.
To add it to many monitors at once, select them on the Monitors page and open the bulk action for integrations. In the Set integrations window, tick PagerDuty and click Save changes.
Troubleshooting
“This integration key for PagerDuty is not valid”
This usually means the key is the wrong type. Use the Events API v2 Integration Key from a PagerDuty service (step 1), not a REST API key. Also check that the selected region matches your PagerDuty account.
The integration stopped working or shows as inactive
PagerDuty is available only on the Team, Scale, and Enterprise plans. If your account moved to a lower plan, the integration becomes inactive. Upgrade to Team or a higher plan to reactivate it.
Alerts don’t show up in PagerDuty
Check that the PagerDuty integration is enabled on the monitor.
Open an incident on the monitor and check its activity log. It shows whether a PagerDuty notification was sent.
If the notification was sent, check the PagerDuty side: the key belongs to the right service, and the region matches.
Response time alerts behave differently from Down alerts
Response time alerts are sent to PagerDuty as warning events, so they don’t open a down-style incident the same way. If Auto-resolve is on, the event sent when response time is back to normal resolves the incident rather than opening a new one.
Still stuck? Contact our support team and include the monitor name and the time of the incident.